I need a solution
I'm currently runnning NB 7.5.0.4. I'm getting the "bptestbpcd: EXIT status = 25 cannot connect on socket" error when running the commands as specified by Symantec.
I'm able to resolve from the master/media server (which is the same) see below
C:\Program Files\Veritas\NetBackup\bin>bpclntcmd -hn hcndc02
host hcndc02: hcndc02 at 192.168.100.226
aliases: hcndc02 192.168.100.226
However I get the following when running the command and checking the logs
16:35:39.583 [3948.3296] <2> bpcd main: accept sock = 380
16:35:39.598 [3660.3528] <2> setup_debug_log: switched debug log file for bpcd
16:35:39.598 [3660.3528] <2> bpcd main: VERBOSE = 0
16:35:39.598 [3660.3528] <2> logparams: C:\Program Files\Veritas\NetBackup\bin\bpcd.exe -standalone
16:35:39.598 [3660.3528] <2> process_requests: offset to GMT 18000
16:35:39.614 [3660.3528] <2> logconnections: BPCD ACCEPT FROM 192.168.100.226.61837 TO 192.168.100.226.13782 fd = 380
16:35:39.614 [3660.3528] <2> process_requests: setup_sockopts complete
16:35:39.614 [3660.3528] <2> bpcd peer_hostname: Connection from host HCNDC02.hcnetwork.org (192.168.100.226) port 61837
16:35:39.614 [3660.3528] <2> bpcd valid_server: comparing hcntape01 and HCNDC02.hcnetwork.org
16:35:39.614 [3660.3528] <4> bpcd valid_server: HCNDC02.hcnetwork.org is not a master server
16:35:39.614 [3660.3528] <16> bpcd valid_server: HCNDC02.hcnetwork.org is not a media server either
16:35:39.614 [3660.3528] <2> process_requests: output socket port number = 3291
16:35:39.614 [3660.3528] <8> vnet_cached_getaddrinfo_and_update: [vnet_addrinfo.c:1583] in failed file cache ERR=10109 NAME=NULL SVC=testdaemon
16:35:39.614 [3660.3528] <8> vnet_cached_get_service_port: [vnet_addrinfo.c:2387] vnet_cached_getaddrinfo failed STAT=6 RV=10109 NAME=testdaemon
16:35:39.614 [3660.3528] <8> is_pbxable_service: [vnet_connect.c:2159] vnet_cached_get_service_port() failed 6 0x6
16:35:39.614 [3660.3528] <8> is_pbxable_service: [vnet_connect.c:2160] service 3291
16:35:39.614 [3660.3528] <8> file_to_cache_item: [vnet_addrinfo.c:6555] fopen() failed ERRNO=2 FILE=C:\Program Files\Veritas\NetBackup\var\host_cache\189\fcd93f89+3291,1,400,2,1,0+192.168.100.226.txt
16:35:39.614 [3660.3528] <2> process_requests: <---- NetBackup 7.5 0 ------------initiated
16:35:39.614 [3660.3528] <2> process_requests: VERBOSE = 0
16:35:39.614 [3660.3528] <2> bpcd exit_bpcd: exit status 46 ----------->exiting
16:35:39.614 [3660.3528] <4> bpcd exit_bpcd: FTL - BPCD EXIT STATUS 46
16:35:39.614 [3660.3528] <16> process_requests: Server access denied
16:35:39.614 [3948.3296] <2> bpcd main: accept sock = 380
16:35:39.645 [2428.3596] <2> setup_debug_log: switched debug log file for bpcd
16:35:39.645 [2428.3596] <2> bpcd main: VERBOSE = 0
16:35:39.645 [2428.3596] <2> logparams: C:\Program Files\Veritas\NetBackup\bin\bpcd.exe -standalone
16:35:39.645 [2428.3596] <2> process_requests: offset to GMT 18000
16:35:39.645 [2428.3596] <2> logconnections: BPCD ACCEPT FROM 192.168.100.226.61839 TO 192.168.100.226.13782 fd = 380
16:35:39.645 [2428.3596] <2> process_requests: setup_sockopts complete
16:35:39.645 [2428.3596] <2> bpcd peer_hostname: Connection from host HCNDC02.hcnetwork.org (192.168.100.226) port 61839
16:35:39.645 [2428.3596] <2> bpcd valid_server: comparing hcntape01 and HCNDC02.hcnetwork.org
16:35:39.645 [2428.3596] <4> bpcd valid_server: HCNDC02.hcnetwork.org is not a master server
16:35:39.645 [2428.3596] <16> bpcd valid_server: HCNDC02.hcnetwork.org is not a media server either
16:35:39.645 [2428.3596] <2> process_requests: output socket port number = 1224
16:35:39.645 [2428.3596] <8> vnet_cached_getaddrinfo_and_update: [vnet_addrinfo.c:1583] in failed file cache ERR=10109 NAME=NULL SVC=testdaemon
16:35:39.645 [2428.3596] <8> vnet_cached_get_service_port: [vnet_addrinfo.c:2387] vnet_cached_getaddrinfo failed STAT=6 RV=10109 NAME=testdaemon
16:35:39.645 [2428.3596] <8> is_pbxable_service: [vnet_connect.c:2159] vnet_cached_get_service_port() failed 6 0x6
16:35:39.645 [2428.3596] <8> is_pbxable_service: [vnet_connect.c:2160] service 1224
16:35:39.645 [2428.3596] <8> file_to_cache_item: [vnet_addrinfo.c:6555] fopen() failed ERRNO=2 FILE=C:\Program Files\Veritas\NetBackup\var\host_cache\189\fcd93f89+1224,1,400,2,1,0+192.168.100.226.txt
16:35:39.645 [2428.3596] <2> process_requests: <---- NetBackup 7.5 0 ------------initiated
16:35:39.645 [2428.3596] <2> process_requests: VERBOSE = 0
16:35:39.645 [2428.3596] <2> bpcd exit_bpcd: exit status 46 ----------->exiting
16:35:39.645 [2428.3596] <4> bpcd exit_bpcd: FTL - BPCD EXIT STATUS 46
16:35:39.645 [2428.3596] <16> process_requests: Server access denied
Any help with this will be highly appreciated
Thanks